Automatic Filling · Europe · CE Certified
IZRC
IZR, EU Configuration
>30
Fills / Min
252
Tray Capacity
<1g
Product Loss
6
HMI Languages
IZRC machine
Operating in North America?
The IZR is the North American variant.
cETLus certification, 120V 60Hz power, and North American documentation. Same core filling technology, configured for the US/Canadian regulatory environment.
View IZR (NA)
§ 01 · What It Does

Automatic cartridge filling, configured for Europe.

The IZRC is the IZR with the certifications and power spec that European regulated markets require. Same throughput, same precision, same OEM-tray compatibility, delivered with CE conformity, 230V power, and operator interface in six languages.

01

CE Conformity

CE certification with a full technical documentation package including the EU Declaration of Conformity, risk assessment, and electrical safety dossier. Ready for EU market deployment from day one.

02

6-Language HMI

Operator interface in English, German, French, Spanish, Italian, and Dutch. Language is selectable per operator; UI strings translated by native speakers working in cannabis-production contexts, not machine translation. Operators can also switch between Fahrenheit and Celsius temperature displays.

03

230V 50Hz Power

Configured for standard European mains: 230VAC 50Hz single-phase. CE-certified power supply. Standard Schuko or IEC C13 connection options available.

04

GMP-Ready Workflow

Same GMP-compliant materials, cleaning workflow, and audit-ready documentation as the IZR. EU GMP Annex 1 alignment for aseptic workflow contexts.

§ 02 · Specifications

Every number, on a document surface.

The IZRC specifications in metric units. Electrical and pneumatic connections conform to European standards. Physical dimensions and throughput match the IZR.

Specifications: IZRC
Model 2026 · Rev. 2025.08
  • Weight34 kg
  • Power Consumption250W
  • Dimensions800 × 460 × 670 mm
  • Pneumatic Min2.8 bar
  • Working Voltage230VAC 50Hz 1Ø
  • Pneumatic Max14.5 bar
  • Reservoir Capacity500 mL
  • Pneumatic Fitting12 mm Quick-Connect
  • Temp Range (Reservoir)Ambient to 93 °C
  • HMI6 languages · °F/°C selectable
  • Cartridge Height Max133 mm
  • Max Cartridges / Tray252
  • Product Loss (per tray)<1 g
§ 03 · Certifications

Certified for the European regulated market.

The IZRC carries CE conformity for EU deployment with a full technical documentation package. GMP-compliant materials and workflow. Core filling technology protected by US Patent 10440989.

CE
CE Conformity
EU Declaration
GMP
GMP-Compliant
Materials · Workflow
®
US Patent
10440989
IEC
IEC Standards
Electrical Safety
§ 04 · Documents

Technical documentation and downloads.

Cut sheet and product brochure are public downloads. Operations & maintenance manuals, startup & qualification documentation, and parts catalogs are available through the online store.

PDF
IZRC Cut Sheet
Public · PDF
PDF
IZRC Product Brochure
Public · PDF
PDF
Operations & Maintenance Manual
Via Store
PDF
Startup & Qualification Documentation
Via Store
SHP
Parts Catalog
Online Store
§ 05 · Related Machines

Variants, alternatives, and upgrades.

IZR
Automatic FillingNA · cETLus
IZR
IZR, NA Configuration
North American variant of this machine. cETLus certified, 120V 60Hz, US-market documentation package. Identical throughput and precision.
FROM $39,000
MCF2C
Semi-AutomaticEU · CE
MCF2C
Semi-Automatic EU
EU-certified semi-automatic alternative for smaller operations or multi-SKU producers needing operator-stepped control.
FROM €12,000
SVH
Semi-AutomaticNA · cETLus
SVH
Semi-Automatic NA
North American semi-automatic alternative. Accepts the Little JIM infusion bolt-on for pre-roll/joint workflows.
FROM $12,500
§ 06 · Technical Q&A

What operators ask before they buy.

What certifications does the IZRC carry?
CE conformity with a full technical documentation package including the EU Declaration of Conformity, risk assessment, and electrical safety dossier. GMP-compliant materials and workflow. Core filling technology is protected under US Patent 10440989.
What languages are supported in the HMI?
English, German, French, Spanish, Italian, and Dutch out of the box. Language is selectable per operator. Translations done by native speakers working in cannabis-production contexts. Additional languages can be added on request for larger deployments. Operators can also switch between Fahrenheit and Celsius temperature displays.
What's the power requirement?
230VAC 50Hz single-phase, 250W consumption. We specify a dedicated 10A circuit for reliable operation. Standard Schuko (CEE 7/4) connection supplied; IEC C13 available on request.
How does the IZRC differ from the IZR?
Same mechanical and fluidic system. The difference is power, certification, and operator interface. IZR is cETLus/120V for North America; IZRC is CE/230V/six-language HMI for the European market. Throughput and precision are identical.
Is the IZRC suitable for EU GMP Annex 1 contexts?
The IZRC materials, surfaces, and workflow patterns support GMP Annex 1 alignment for aseptic-workflow contexts. A GMP documentation package is included. Specific validation for your site's GMP program is the operator's responsibility.
What's the typical lead time to Europe?
Lead time depends on the current production queue and destination country. Machines ship from Portland, Oregon via air or sea freight. Contact sales through the quote form for current delivery windows specific to your configuration and country.
What OEM cartridge packaging does the IZRC work with?
Standard OEM cartridge packaging trays, 252-device capacity, 133 mm maximum cartridge height. Accommodates the full range of common cartridge form factors available in the European regulated market.
Ready to Quote

Put an IZRC on your European production floor.

Request a quote with your configuration details and destination country, or download the cut sheet and CE documentation for your install planning. You're talking directly with the manufacturer, no distributor chain.